Services
What do you need tested?
Purpose-built rigs for subsea equipment, and a laboratory for the fluids and the materials they touch. Pick a service below.
Equipment
Laboratory
Equipment · Directional control valves
DCV testing
SFS tests directional control valves (DCVs) and subsea control fluids on independent test rigs, running up to 6 valves at once at pressures up to 20,000 psi (1,379 bar) for fluid qualification, FAT, fluid changeovers and FEED work.
Up to 6 DCVs at once, at pressures up to 20,000 psi (1,379 bar).
- Fluid qualification, FAT, fluid changeovers and FEED work
- Cyclic, endurance and long-term hold-open testing
- Built-in cleanliness monitoring and recirculation
20,000 psi
Pilot and control line test pressure
We have a number of test rigs capable of testing up to 6 DCVs simultaneously across a range of temperatures and pressures. The rigs are used for fluid qualification testing, FAT, fluid changeovers, FEED work and product development on new fluid or valve designs.
Rig capabilities
- Capacity of up to 6 valves per test rig
- Pilot and control line pressure up to 20,000 psi
- Independent pressure settings for pilot and control
- Data acquisition sampling at 2,000 samples per second
- Built-in cleanliness monitor continuously checks the system
- Pulsation dampers on pilot and control lines
- Recirculation system holds the specified system cleanliness
Typical testing
- High and low pressure testing
- Long-term hold-open testing with valve closing trace
- High and low cycle endurance testing
- Full OEM factory acceptance testing
- High and low temperature testing
- Contaminated fluid testing
- Corrosion, electrical and solenoid testing